ECU 000637.06 – Current in Pump Position Sensor Too High. John Deere System Advisory.

ECU 000637.06 (ECU 637.06)

Code: 000637.06

Shortcode: 637.06

Description:

This error code, ECU 000637.06, occurs when the ECU detects high current on the pump position sensor wiring, indicating low circuit resistance, typically due to a short to ground. This fault can disrupt accurate readings from the pump position sensor.

Reaction:

The ECU may modify engine operations to compensate for the erroneous sensor data and protect engine components from potential damage.

Recommendations:

  • Inspect for Short Circuits: Examine the wiring for the pump position sensor for signs of shorts to ground or other conductive surfaces.
  • Measure Circuit Resistance: Use diagnostic tools to confirm low resistance in the circuit and locate the short.
  • Repair or Replace Damaged Wiring: Correct any identified issues by repairing or replacing faulty wiring or connectors.
  • Confirm Sensor Functionality: Test the sensor after repairs to ensure it provides accurate data to the ECU.
  • Reset ECU and Conduct System Tests: After resolving the issue, reset the ECU and perform comprehensive tests to ensure the system operates without further errors.

Note:

Proper maintenance of sensor wiring and connections is vital to prevent short circuits and ensure accurate sensor data.


Control Units: John Deere