ECU 000637.06 – Current in Pump Position Sensor Too High. John Deere System Advisory.
ECU 000637.06 (ECU 637.06)
Code: 000637.06
Shortcode: 637.06
Description:
This error code, ECU 000637.06, occurs when the ECU detects high current on the pump position sensor wiring, indicating low circuit resistance, typically due to a short to ground. This fault can disrupt accurate readings from the pump position sensor.
Reaction:
The ECU may modify engine operations to compensate for the erroneous sensor data and protect engine components from potential damage.
Recommendations:
- Inspect for Short Circuits: Examine the wiring for the pump position sensor for signs of shorts to ground or other conductive surfaces.
- Measure Circuit Resistance: Use diagnostic tools to confirm low resistance in the circuit and locate the short.
- Repair or Replace Damaged Wiring: Correct any identified issues by repairing or replacing faulty wiring or connectors.
- Confirm Sensor Functionality: Test the sensor after repairs to ensure it provides accurate data to the ECU.
- Reset ECU and Conduct System Tests: After resolving the issue, reset the ECU and perform comprehensive tests to ensure the system operates without further errors.
Note:
Proper maintenance of sensor wiring and connections is vital to prevent short circuits and ensure accurate sensor data.