ECU 001761.03 – DEF Tank Fluid Level Sensor, Voltage Too High. John Deere System Advisory.
ECU 001761.03 (ECU 1761.03)
Code: 001761.03
Shortcode: 1761.03
Description:
Error code ECU 001761.03 is triggered when the ECU detects that the voltage at the DEF tank fluid level sensor is too high, suggesting a short to a 12V power source. This abnormal voltage reading can lead to inaccurate DEF level readings, affecting emissions control.
Reaction:
Error code ECU 001761.03 is triggered when the ECU detects that the voltage at the DEF tank fluid level sensor is too high, suggesting a short to a 12V power source. This abnormal voltage reading can lead to inaccurate DEF level readings, affecting emissions control.
Recommendations:
- Inspect Sensor Wiring: Check the wiring to the DEF tank fluid level sensor for signs of damage or wear that could cause a short to a power source.
- Measure Sensor Voltage: Use a multimeter to verify the voltage at the sensor. High voltage readings confirm a short to 12V.
- Check for Wiring Short Circuits: Inspect the entire DEF level sensor circuit for shorts to the vehicle’s power system.
- Replace Damaged Wiring or Sensor: Repair or replace any damaged wiring or the sensor itself to correct the high voltage issue.
- Reset ECU and Perform Diagnostic Tests: After repairs, reset the ECU to clear the error code and perform diagnostic tests to ensure the sensor is functioning correctly and providing accurate readings.
Note:
Proper function of the DEF fluid level sensor is crucial for accurate DEF monitoring and effective emissions control. Regular checks and maintenance are essential to prevent electrical issues.