ECU 005128.06 – Sensor Supply Voltage 10, Resistance Too Low. John Deere System Advisory.
ECU 005128.06 (ECU 5128.06)
Code: 005128.06
Shortcode: 5128.06
Description:
This diagnostic trouble code indicates that the resistance in the supply voltage circuit for Sensor 10 is too low, typically indicating a short to ground. This condition can affect the proper functioning of the sensor and its associated systems.
Reaction:
The ECU may limit or adjust the operation of the systems associated with Sensor 10 to manage the low circuit resistance and ensure safe operation.
Recommendations:
- Inspect Wiring and Connections: Check for damaged, frayed, or loose wiring and connectors associated with Sensor 10. Repair or replace as necessary.
- Test Sensor Element: Use diagnostic tools to test Sensor 10 for proper resistance and continuity. Replace the sensor if it is faulty.
- Check for Short Circuits: Inspect the circuit for any points where wires may be touching ground, causing a short circuit. Repair or insulate as needed.
- Verify Electrical Supply: Ensure that the electrical supply to the sensor is stable and within specifications.
- Reset ECU and Monitor System: After resolving the issue, reset the ECU to clear the fault code and monitor the system to ensure normal operation.
Note:
Proper electrical function and resistance in sensor circuits are crucial for accurate data collection and system performance. Regular inspections and timely maintenance can help prevent resistance-related issues.