This diagnostic trouble code, RPT 523815.01, is generated when the PAP control software measures a supply voltage of less than 3 V at the output to the solenoid for PTO speed 3 when the solenoid is turned on. This indicates a supply voltage fault or a potential issue with the solenoid circuit.
- John Deere error RPT codes
RPT 523815.00 – Solenoid for PTO Speed 3, Current Overload Protection Active at PAP Control Software
John Deere error RPT codesThis diagnostic trouble code, RPT 523815.00, is generated when the PAP (Power Accessory Point) control software measures a total current above 40 A at the outputs to the solenoids for PTO speeds. This indicates a short to ground or a defective component in one of the monitored circuits.
- John Deere error RPT codes
This diagnostic trouble code, RPT 523814.12, is generated when the PAP control software measures a current of more than 1 A at the output to the solenoid for PTO speed 2 when the solenoid is turned off. This indicates a short in the circuit or an internal fault of the control software.
- John Deere error RPT codes
This diagnostic trouble code, RPT 523814.09, is generated when there is a data transfer problem between the PAP (Power Accessory Point) control software and the RPT control software. The issue arises when the RPT control software intermittently or completely fails to receive one, several, or all of the expected CAN messages from the PAP. This…
- John Deere error RPT codes
This diagnostic trouble code, RPT 523814.03, is generated when the PAP (Power Accessory Point) control software detects a voltage that is too high (12 volts) at the output to the solenoid for PTO speed 2 when the solenoid is turned on. This indicates a circuit that is open or shorted to 12 volts.
- John Deere error RPT codes
This diagnostic trouble code, RPT 523814.01, is generated when the PAP control software measures a supply voltage of less than 2 V at the output to the solenoid for PTO speed 2 when the solenoid is turned on. This indicates a supply voltage fault or a potential issue with the solenoid circuit.
RPT 523814.00 – Solenoid for PTO Speed 2, Current Overload Protection Active at PAP Control Software
John Deere error RPT codesThis diagnostic trouble code, RPT 523814.00, is generated when the PAP (Power Accessory Point) control software measures a total current above 40 A at the outputs to the solenoids for PTO speeds. This indicates a short to ground or a defective component in one of the monitored circuits.