This error code, SIC 523835.07, is triggered when a nonexistent function (S134/152 Switches for Remote Control of ESCV) is activated at address SIC044. This indicates an attempt to use an unassigned or incorrect function within the control system.
- John Deere error SIC codes
This error code, SIC 523829.14, is saved when there is a problem in transmitting data between the stepper motor of EICV 1 and the control unit. Intermittently, the stepper motor cannot establish any connection to the control unit via the CAN BUS for ESCV/EICV. The stepper motor itself is not responsible for this diagnostic trouble…
- John Deere error SIC codes
This error code, SIC 523829.09, is generated when there is a problem in transmitting data between the stepper motor of EICV 1 (Electro-Hydraulic Integrated Control Valve) and the control unit. Following a successful initialization (link made after ignition ON), the control unit fails to establish a connection to the stepper motor, or makes only intermittent…
- John Deere error SIC codes
This error code, SIC 523828.14, is saved when there is a problem in transmitting data between the stepper motor of EICV 2 and the control unit. Intermittently, the stepper motor cannot establish any connection to the control unit via the CAN BUS for ESCV/EICV. The stepper motor itself is not responsible for this diagnostic trouble…
- John Deere error SIC codes
This error code, SIC 523828.09, is generated when there is a problem in transmitting data between the stepper motor of EICV 2 (Electro-Hydraulic Integrated Control Valve) and the control unit. Following a successful initialization (link made after ignition ON), the control unit fails to establish a connection to the stepper motor, or makes only intermittent…
- John Deere error SIC codes
This error code, SIC 523827.14, is saved when there is a problem in transmitting data between the stepper motor of EICV 3 (Electro-Hydraulic Integrated Control Valve) and the control unit. Intermittently, the stepper motor cannot establish any connection to the control unit via the CAN BUS for ESCV/EICV. The stepper motor itself is not responsible…
- John Deere error SIC codes
This error code, SIC 523827.09, is generated when there is a problem in transmitting data between the stepper motor of EICV 3 (Electro-Hydraulic Integrated Control Valve) and the control unit. Following a successful initialization (link made after ignition ON), the control unit fails to establish a connection to the stepper motor, or makes only intermittent…
- John Deere error SIC codes
This error code, SIC 523825.14, is saved when there is a problem in transmitting data between the stepper motor of ESCV 1 and the control unit. Intermittently, the stepper motor cannot establish any connection to the control unit via the CAN BUS for ESCV/EICV. The stepper motor itself is not responsible for this diagnostic trouble…
- John Deere error SIC codes
This error code, SIC 523825.09, is generated when there is a problem in transmitting data between the stepper motor of ESCV 1 (Electro-Hydraulic Section Control Valve) and the control unit. Following a successful initialization (link made after ignition ON), the control unit fails to establish a connection to the stepper motor, or makes only intermittent…
- John Deere error SIC codes
This error code, SIC 523819.14, is saved when there is a problem in transmitting data between the stepper motor of ESCV 2 and the control unit. Intermittently, the stepper motor cannot establish any connection to the control unit via the CAN BUS for ESCV/EICV. The stepper motor itself is not responsible for this diagnostic trouble…