This error code, SIC 523794.04, is triggered when power module PC5 measures more than 20 amps at the power output to the ESCV (Electro-Hydraulic Section Control Valve) stepper motors. This indicates that the circuit is shorted to ground or there is a defective component in the circuit.
- John Deere error SIC codes
- John Deere error SIC codes
This error code, SIC 523794.03, is generated when the power module PC5 measures voltage at the power output to the ESCV (Electro-Hydraulic Section Control Valve) stepper motors while they are supposed to be off. This indicates a possible short circuit or a defective component in the circuit.
- John Deere error SIC codes
This error code, SIC 523794.01, is generated when the power module PC5 registers a supply voltage of less than 3 volts at the ESCV (Electro-Hydraulic Section Control Valve) stepper motor outputs when switching on the ESCV stepper motors (A36, A39). This indicates an issue with the power supply to the ESCV stepper motors.
- John Deere error SIC codes
This error code, SIC 523794.00, is triggered when power module PC5 measures more than 20 amps at the power output to the ESCV (Electro-Hydraulic Section Control Valve) stepper motors. This indicates that the circuit is shorted to ground or there is a defective component in the circuit.
- John Deere error SIC codes
This error code, SIC 523790.12, is generated when the power module PC5 measures a current of more than 1 amp at the power supply output to the EICV (Electro-Hydraulic Integrated Control Valve) stepper motors (lead 7045) with the multifunction lever not actuated. This indicates a short in the circuit or an internal fault in the…
- John Deere error SIC codes
This error code, SIC 523790.09, is generated when there is a problem transferring data between the SIC control unit and the power module PC5. The reception of one, several, or all of the CAN messages transmitted by the SIC to the power module PC5 is intermittent or nonexistent, which could be due to a loose…
- John Deere error SIC codes
This error code, SIC 523790.05, is generated when the power module PC5 does not measure current at the power output to the EICV (Electro-Hydraulic Integrated Control Valve) stepper motors. This indicates that the circuit is open or there is a defective component in the circuit.
- John Deere error SIC codes
This error code, SIC 523790.04, is triggered when power module PC5 measures more than 20 amps at the power output to the EICV (Electro-Hydraulic Integrated Control Valve) stepper motors. This indicates that the circuit is shorted to ground or there is a defective component in the circuit.