PTA 000604.03 – Transmission Enable Signal, Voltage Too High
PTA 000604.03 (PTA 604.03)
Code: 000604.03
Shortcode: 604.03
Description:
This diagnostic trouble code is generated when the PTA control software detects that the voltage at the transmission enable signal is too high. This indicates a short to a positive lead in the circuit of the transmission enable signal.
Reaction:
Limited or no function of the transmission until the error is corrected, indicating a significant issue with the transmission enable signal circuit.
Recommendations:
Inspect Transmission Enable Circuit:
- Check the circuit for any short circuits to positive leads.
- Repair any identified issues in the circuit.
Test Transmission Enable Relay:
- Verify the relay’s voltage output using a multimeter.
- Replace the relay if it is producing abnormally high voltage readings.
Examine Wiring and Connectors:
- Inspect all wiring and connectors associated with the transmission enable signal for signs of damage or corrosion.
- Repair or replace as necessary to ensure proper electrical connections.
Ensure Proper Grounding:
- Verify that the transmission enable circuit is properly grounded.
- Correct any grounding issues that may be causing voltage irregularities.
Note: