SSU 000517.09 – Incorrect CAN BUS Message, Travel Speed from StarFire ITC Receiver
SSU 000517.09 (SSU 517.09)
Code: 000517.09
Shortcode: 517.09
Description:
This diagnostic trouble code (DTC), SSU 000517.09, is generated when the travel speed data placed on the ISOBUS by the StarFire ITC receiver cannot be read. This indicates a communication issue between the StarFire ITC receiver and the rest of the system.
Reaction:
When this error is detected, the equipment may not correctly display or process travel speed information, which can affect operations that rely on accurate speed data.
Recommendations:
Verify ISOBUS Communication:
- Inspect the ISOBUS wiring and connectors for any signs of damage, loose connections, or corrosion.
- Use diagnostic tools to check for continuity and proper voltage levels in the ISOBUS lines.
Check StarFire ITC Receiver:
- Ensure that the StarFire ITC receiver is functioning properly and transmitting accurate data.
- Check for any firmware updates for the StarFire ITC receiver and apply them as needed.
Update Software:
- Ensure that all related software, including that of the ISOBUS and the StarFire ITC receiver, is up-to-date.
Replace Faulty Components:
- If the StarFire ITC receiver or any components within the ISOBUS network are found to be defective, replace them with new, genuine parts.
Consult Technical Support:
- If the error persists after performing the above steps, consult technical support or the manufacturer for further assistance in identifying and resolving the issue.
Note:
- Regular maintenance and inspection of the ISOBUS wiring and connected components can help prevent this issue.