TIA 000974.02 – Hand Throttle Potentiometer, Voltages at Channel 1 and Channel 2 Not in the Correct Ratio
TIA 000974.02 (TIA 974.02)
Code: 000974.02
Shortcode: 974.02
Description:
This diagnostic trouble code (DTC) is generated when the control software detects a mismatch between the output signals of the hand throttle potentiometer. The voltage at channel 1 must be double the voltage at channel 2. A discrepancy in this ratio indicates a problem with the potentiometer or its associated wiring.
Reaction:
Limited or no function of the hand throttle potentiometer, affecting throttle control.
Recommendations:
Inspect Hand Throttle Potentiometer:
- Verify the physical condition and operation of the hand throttle potentiometer.
- Replace the potentiometer if it is faulty or damaged.
Check Wiring and Connections:
- Inspect the wiring and connectors between the hand throttle potentiometer and the control unit for damage, corrosion, or loose connections.
- Repair or replace any faulty wiring or connectors.
Measure Voltage Outputs:
- Use a multimeter to measure the voltages at channel 1 and channel 2 of the hand throttle potentiometer.
- Ensure that the voltage at channel 1 is exactly double the voltage at channel 2. If not, replace the potentiometer.
Update Control Software:
- Ensure the control software is up-to-date to handle the correct potentiometer signals and ratios.
Consult Technical Support:
- If the issue persists after performing the above checks, consult technical support for further diagnostic procedures or potential software issues.
Note: