TIA 000974.03 – Hand Throttle Potentiometer, Voltage at Channel 1 Too High
TIA 000974.03 (TIA 974.03)
Code: 000974.03
Shortcode: 974.03
Description:
This diagnostic trouble code (DTC) is generated when the control software measures a voltage of more than 4.5 V at the signal input from channel 1 of the hand throttle potentiometer. This high voltage reading indicates a potential problem with the signal lead or the ground connection of the potentiometer.
Reaction:
Limited or no function of the hand throttle potentiometer, affecting throttle control.
Recommendations:
Inspect Signal Lead and Ground Connection:
- Verify the integrity and connection of the signal lead and ground connection.
- Repair or replace any damaged or corroded wiring and connectors.
Measure Voltage at Signal Input:
- Use a multimeter to measure the voltage at channel 1 of the hand throttle potentiometer.
- Ensure the voltage is within the expected range (typically 0.5 to 4.5 V). If it exceeds 4.5 V, further investigation is required.
Check Potentiometer:
- Inspect the hand throttle potentiometer for any signs of wear or damage.
- Replace the potentiometer if it is malfunctioning.
Update Control Software:
- Ensure that the control software is up-to-date with the latest version from the manufacturer.
Consult Technical Support:
- If the issue persists, consult technical support for further diagnostic procedures or potential hardware issues.
Note:
Regular inspection and maintenance of the hand throttle potentiometer and its wiring can prevent high voltage issues. Environmental factors such as moisture or extreme temperatures can also affect electrical connections.