TIQ 523961.07 – Park Lock, Malfunction
TIQ 523961.07 (TIQ )
Code: 523961.07
Shortcode:
Description:
This diagnostic trouble code is generated under two specific conditions:
- If the park lock does not engage despite the TIQ control software commanding the park position and the tractor’s ground speed allowing for engagement.
- If a ground speed signal is detected even though the park position is commanded and the TIQ control software has received confirmation that the park lock is engaged.
Reaction:
If an operator error is identified, the tractor may be moved again after shifting the reverse drive lever and park lock into the neutral position.
Recommendations:
- Inspect Park Lock Mechanism:
- Check the park lock mechanism for any signs of wear, damage, or obstruction.
- Ensure the park lock is able to engage and disengage smoothly.
- Verify Ground Speed Signal:
- Ensure that the ground speed sensor is functioning correctly and providing accurate signals.
- Replace the sensor if it is found to be faulty.
- Check Wiring and Connections:
- Inspect the wiring and connections between the park lock mechanism and the control module.
- Repair or replace any damaged or loose connections.
- Reset Control Module:
- Perform a soft reset of the control module by cycling the power to clear any transient errors.
- Operator Procedure:
- Ensure that the operator follows the correct procedure by moving the reverse drive lever and park lock into the neutral position before attempting to move the tractor again.
Note:
Regular maintenance and inspection of the park lock mechanism and associated components can prevent malfunctions and ensure reliable operation.