TIQ 523961.07 – Park Lock, Malfunction

TIQ 523961.07 (TIQ )

Code: 523961.07

Shortcode:

Description:

This diagnostic trouble code is generated under two specific conditions:

  1. If the park lock does not engage despite the TIQ control software commanding the park position and the tractor’s ground speed allowing for engagement.
  2. If a ground speed signal is detected even though the park position is commanded and the TIQ control software has received confirmation that the park lock is engaged.

Reaction:

If an operator error is identified, the tractor may be moved again after shifting the reverse drive lever and park lock into the neutral position.

Recommendations:

  • Inspect Park Lock Mechanism:
    • Check the park lock mechanism for any signs of wear, damage, or obstruction.
    • Ensure the park lock is able to engage and disengage smoothly.
  • Verify Ground Speed Signal:
    • Ensure that the ground speed sensor is functioning correctly and providing accurate signals.
    • Replace the sensor if it is found to be faulty.
  • Check Wiring and Connections:
    • Inspect the wiring and connections between the park lock mechanism and the control module.
    • Repair or replace any damaged or loose connections.
  • Reset Control Module:
    • Perform a soft reset of the control module by cycling the power to clear any transient errors.
  • Operator Procedure:
    • Ensure that the operator follows the correct procedure by moving the reverse drive lever and park lock into the neutral position before attempting to move the tractor again.

Note:

Regular maintenance and inspection of the park lock mechanism and associated components can prevent malfunctions and ensure reliable operation.


Control Units: John Deere

John Deere Parts