TIQ 524254.03 – Transmission Enable Circuit Voltage Too High

TIQ 524254.03 (TIQ )

Code: 524254.03

Shortcode:

Description:

This diagnostic trouble code is generated when the transmission enable circuit voltage is too high, indicating a circuit open or shorted to 12 volts.

Reaction:

When this fault is detected, the tractor transmission cannot be shifted, and the 3rd gear is engaged automatically, resulting in limited transmission function.

Recommendations:

  • Inspect Transmission Enable Circuit:
    • Check for any open circuits or shorts to 12 volts in the transmission enable circuit.
    • Repair or replace any faulty wiring or components.
  • Verify Voltage Levels:
    • Use a multimeter to check the voltage levels in the transmission enable circuit.
    • Ensure that the voltage is within the acceptable range.
  • Check Control Unit:
    • Inspect the control unit for any internal faults that might cause high voltage.
    • Replace the control unit if necessary.
  • Inspect Connectors:
    • Ensure all connectors in the transmission enable circuit are secure and free from corrosion.
    • Clean or replace connectors as needed.

Note:

Regular inspection of the transmission enable circuit can help prevent voltage issues and ensure reliable operation of the transmission system.


Control Units: John Deere