TIQ 524254.04 – Transmission Enable Circuit Voltage Too Low
TIQ 524254.04 (TIQ )
Code: 524254.04
Shortcode:
Description:
This diagnostic trouble code is generated when the voltage supply of 12-volt components in the transmission enable circuit is too low, indicating a short to ground or an internal fault of the control unit.
Reaction:
When this fault is detected, the tractor transmission cannot be shifted, and the 3rd gear is engaged automatically, resulting in limited transmission function.
Recommendations:
- Inspect Transmission Enable Circuit:
- Check for any shorts to ground in the transmission enable circuit.
- Repair or replace any faulty wiring or components.
- Verify Voltage Supply:
- Use a multimeter to check the voltage supply to the 12-volt components.
- Ensure that the voltage is within the acceptable range.
- Check Control Unit:
- Inspect the control unit for any internal faults that might cause low voltage.
- Replace the control unit if necessary.
- Inspect Connectors:
- Ensure all connectors in the transmission enable circuit are secure and free from corrosion.
- Clean or replace connectors as needed.
Note:
Regular inspection and maintenance of the transmission enable circuit can help prevent voltage issues and ensure reliable operation of the transmission system.