TSC 003509.03 – 5volt Power Supply to TLS Sensors, Voltage Too High
TSC 003509.03 (TSC 3509.03)
Code: 003509.03
Shortcode: 3509.03
Description:
This diagnostic trouble code, TSC 003509.03, is triggered when the voltage measured at the positive lead of the power supply to the 5-volt components (TLS position sensor B53 and TLS oil pressure sensor B167) exceeds 5.25 volts. This indicates a possible circuit short to a supply lead or an internal interruption at the TSC.
Reaction:
When this error occurs, the affected sensors may not operate correctly, potentially leading to incorrect readings and impaired functionality of the TLS system.
Recommendations:
Inspect Power Supply Circuit:
- Check for Shorts:
- Examine the wiring for any signs of short circuits to a supply lead.
- Repair any identified shorts in the circuit.
Inspect Sensors:
- Check Sensor Connections:
- Ensure that the TLS position sensor B53 and TLS oil pressure sensor B167 are properly connected and not damaged.
- Replace any faulty sensors.
Verify TSC Internal Circuitry:
- Check for Internal Faults:
- Inspect the internal circuitry of the TSC for any interruptions or faults.
- Repair or replace the TSC if necessary.
Note:
Ensuring the stability of the 5-volt power supply to the TLS sensors is crucial for accurate sensor readings and proper system functionality. Regular inspections and maintenance of the power supply circuit and sensors are recommended.