TSC 523951.02 – Calibration (TLS), Front Axle Moves in Wrong Direction
TSC 523951.02 (TSC )
Code: 523951.02
Shortcode:
Description:
This diagnostic trouble code, TSC 523951.02, is triggered when the TSC (front-wheel drive axle with TLS) perceives motion in the wrong direction during calibration or bleeding. This can indicate that the plugs are mixed up at the solenoid valves, there is a problem in the raising/lowering solenoid valve circuit (TLS), the pressure buildup/reduction circuit (TLS), or there is a problem in the hydraulic circuit of the TLS front-wheel drive axle.
Reaction:
When this error occurs, the front axle calibration or bleeding process fails, potentially leading to incorrect alignment and operational issues.
Recommendations:
Check Solenoid Valve Connections:
- Verify Correct Connections:
- Ensure that the plugs for the solenoid valves are correctly connected.
- Correct any mixed-up connections.
Inspect Solenoid Valve Circuit:
- Check for Circuit Issues:
- Examine the wiring for any signs of issues in the raising/lowering or pressure buildup/reduction circuits.
- Repair any identified issues in the circuit.
Inspect Hydraulic Circuit:
- Check for Hydraulic Problems:
- Inspect the hydraulic circuit for any signs of blockages, leaks, or other issues.
- Repair any identified problems in the hydraulic circuit.
Note:
Proper calibration and bleeding of the TLS front-wheel drive axle are essential for accurate alignment and smooth operation. Regular inspections and maintenance of the solenoid valves and hydraulic circuit are necessary to prevent calibration faults.