TSC 523972.13 – Cab Suspension in Level Position, Voltage Out of Range (During Calibration)
TSC 523972.13 (TSC )
Code: 523972.13
Shortcode:
Description:
This diagnostic trouble code, TSC 523972.13, is triggered when, at the end of calibration, the TSC (cab suspension) detects a level position voltage that is out of range (i.e., not between 2 and 3 volts).
Reaction:
When this error occurs, the cab suspension may not level correctly, potentially leading to operational issues and discomfort.
Recommendations:
Inspect Cab Position Sensor:
- Check Sensor Output:
- Verify that the signal output of the cab position sensor B110 falls within the 2-3 volts range when the cab suspension is in the level position.
- Recalibrate or replace the sensor if necessary.
Inspect Sensor Circuit:
- Check for Circuit Issues:
- Examine the wiring and connections of the cab position sensor for any signs of damage, loose connections, or corrosion.
- Repair or replace any faulty components in the circuit.
Verify Calibration Process:
- Ensure Correct Calibration Procedure:
- Follow the manufacturer’s instructions for the calibration process.
- Ensure all necessary conditions (engine speed, tractor stationary) are met during calibration.
Note:
Ensuring the cab suspension reaches the correct level position voltage is crucial for proper operation. Regular inspections and maintenance of the cab position sensor and its circuit are essential.