This diagnostic trouble code is generated when the PTA control software registers a current value at the solenoid valve for the disk brake that does not correspond with the switch status of the BG disk brake, indicating that the solenoid valve circuit is open.
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a voltage value at the solenoid valve for the disk brake that does not correspond with the switch status of the BG disk brake. This indicates a short to ground in the solenoid valve circuit.
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a voltage value at the solenoid valve for the disk brake that does not correspond with the switch status of the BG disk brake. This indicates a short to a positive lead or a defective solenoid valve for the disk brake. The fault…
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software detects that the voltage at channel 2 of the transmission output speed sensor is too high. This indicates a supply voltage problem or that the sensor circuit is open or shorted to a positive lead.
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a current value at the proportional solenoid valve 1 that does not correspond with the commanded working position of the hydrostatic unit, indicating that the circuit of the proportional solenoid valve 1 is open. If diagnostic trouble code PTA 524107.05 is also stored,…
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a voltage value at the proportional solenoid valve 1 that does not correspond with the commanded working position of the hydrostatic unit, indicating a short to ground in the circuit of the proportional solenoid valve 1.
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a voltage value at the proportional solenoid valve 1 that does not correspond with the commanded working position of the hydrostatic unit. This indicates a general problem with the supply voltage (BAT) or that the circuit of proportional solenoid valve 1 is shorted…
- John Deere error PTA codes
This diagnostic trouble code is generated when the PTA control software registers a current value at the proportional solenoid valve 2 that does not correspond with the commanded working position of the hydrostatic unit. This indicates that the circuit of the proportional solenoid valve 2 is open. If diagnostic trouble code PTA 524108.05 is also…