This error code, EPC 001713.15, is generated when the filter alarm level 1 switch at the hydraulic oil filter was closed for more than three seconds at a hydraulic oil temperature above 28°C (82°F) and an engine speed above 700 rpm. The switch closes at a differential filter pressure of 350 kPa (3.5 bar; 51…
- John Deere error EPC codes
- John Deere error EPC codes
This error code, EPC 001713.02, is generated when, with an open filter alarm level 1 switch (350 kPa; 3.5 bar; 51 psi) at the hydraulic oil filter, the filter alarm level 2 switch (450 kPa; 4.5 bar; 65 psi) at the hydraulic oil filter has been closed for more than 3 seconds at a hydraulic…
- John Deere error EPC codes
This error code, EPC 001079.04, is generated when the EPC measures less than 4.8 volts at the positive lead of the power supply to the 5-volt components (clutch pedal potentiometer B65, accelerator pedal potentiometer B79, hand throttle potentiometer B96, and enable pressure sensor B105). This indicates a short to ground in the circuit.
- John Deere error EPC codes
This error code, EPC 001079.03, is generated when the EPC measures more than 5.2 volts at the positive lead of the power supply to the 5-volt components (clutch pedal potentiometer B65, accelerator pedal potentiometer B79, hand throttle potentiometer B96, and enable pressure sensor B105). This indicates that the circuit is shorted to a positive supply…
- John Deere error EPC codes
This error code, EPC 001079.02, is generated when the control unit detects several incorrect output signals from the 5-volt components (clutch pedal potentiometer B65, accelerator pedal potentiometer B79, hand throttle potentiometer B96, and enable pressure sensor B105). This indicates a problem with the 5-volt power supply.
- John Deere error EPC codes
This error code, EPC 000974.03, is generated when the control unit measures a voltage in excess of 4.7 volts at the signal input of the hand throttle potentiometer (B96, lead 6018). This indicates a short to a positive lead, an open circuit, or a problem with the ground connection in the potentiometer’s circuit.
- John Deere error EPC codes
This error code, EPC 000737.05, indicates that the control unit has registered an open circuit at the signal input of the gear selector solenoid valve K2 (Y39). This results in insufficient current flowing to the solenoid valve, potentially affecting its operation.
- John Deere error EPC codes
This error code, EPC 000736.05, indicates that the control unit has registered an open circuit at the signal input of the gear selector solenoid valve K1 (Y40). This results in insufficient current flowing to the solenoid valve, potentially affecting its operation.